- Drawing
- Specification
MODEL | PIPE SIZE | CV | ORIFICE | FLUID TEMP. (ºC) |
Operating Pressure kgf-cm2 (bar) | Dimension (mm) |
Weight (kg) |
||||||
WATER | AIR | STEAM | LIGHT OIL | GAS | L | H | D | ||||||
UPS-15 | 1/2" | 4.0 | 17mm | -5ºC~+185ºC | 0.5~10 | 0.5~10 | 0.5~10 | 0.5~10 | 82 | 118 | 48 | 1.32 | |
UPS-20 | 3/4" | 6.0 | 17mm | -5ºC~+185ºC | 0.5~10 | 0.5~10 | 0.5~10 | 0.5~10 | 82 | 120 | 48 | 1.44 | |
UPS-25 | 1" | 12 | 22mm | -5ºC~+185ºC | 0.5~10 | 0.5~10 | 0.5~10 | 0.5~10 | 100 | 135 | 48 | 2.13 |
- Material
PARTS | Coil | Tube | Spring | Core | Plug | Piston | Piston Plug | Valve Body |
MATERIAL | Special Copper Wire (H Class) |
Stainless Steel | Stainless Steel | Stainless Steel | PTFE | Brass | PTFE | Forged Brass |
- Description
- UPS series is multiplex, pilot operated piston, conductive, and normally close (NC) 2/2 solenoid valve
- Specially suitable for frequent operation
- Availability of fluid: water, air, steam, light oil
- Acceptable for customization VITON, Silicone and EPDM plug
- Cautions
- Minimum pressure to operate: over 0.5kgf-cm2
- Before installation depressurize the piping system and clean internally.
- For the protection of the equipment install a strainer or filter suitable for the service involved in the inlet side as close to the solenoid valve as possible.
- AC voltage tolerance: +/- 10%; DC voltage tolerance: +/- 1%
- All standard solenoid valve MUST be mounted vertically upright.
- Not suitable for fluid as below:
- Liquid status when it is at high temperature; solid status when it is cool.
- Corrosive fluid
- Viscosity over 20cst